Chapter 14: T1 Interface Configuration Steps
August 1997 Page 14-1
2524UM
Chapter 14: T1 Interface Configuration
Steps
Introduction
This chapter describes how to configure the AI2524 for fractional T1.
Configure
Fractional T1
Configuration Overview
This section describes how to configure fractional T1 and T1 (FT1/T1
service modules installed the AI2425 router. The tasks associated with
configuring T1 include:
z
Specify the Clock Source
z
Enable Data Inversion Before Transmission
z
Specify the Frame Type of a FT/T1 Line
z
Specify the CSU Line Build Out
z
Specify FT1/T1 Line-Code Type
z
Enable Remote Alarms
z
Enable Loopcodes that Initiate Remote Loopbacks
z
Specify Timeslots
Specify the Clock Source
To specify the clock source for the FT1/T1 CSU/DSU internal clock
or the line clock, type this in interface configuration mode:
service-module t1 clock source {internal |
line}
Enable Data Inversion Before Transmission
Data inversion is used to guarantee the T1s density requirement on an
AMI line when using bit-oriented protocols such as High-Level Data
Link Control (HDLC), Point-to-Point Protocol (PPP), X.25, and
Frame Relay.